Method Pros Cons
Signal Level + Test can be automated
+ Specialized test equipment not req’d
+ Aligns well with coverage prediction
- Does not consider localized noise and
interference environments
- Does not verify digital system components
and overall system operation
- Far removed from user experience (i.e. may
not be reflective of real voice quality)
- Typically only used to measure one path
direction
Bit Error Rate or
Frame Error Rate
+ Test can be automated
+ Good measure of C/(I+N)
+ Verifies some of the digital elements
- Specialized test equipment required
- Does not verify all system elements
- Somewhat abstract from actual user
experience
- Typically only used to measure one path
direction
Voice (DAQ)
Testing
+ Reflects end user experience
+ Incorporates roaming impacts
+ Automated data collection
+ Specialized test equipment not req’d
+ Exercises all system elements
-- Data evaluation is manual , subjective and
time consuming, or
-- Automated using expensive software
- Difficult to ‘mine’ data to identify problem
origins (should they exist)
Zobrazit stránku 16